[Specifications]:4AI+2DO
[Interface mode]:RS232
[Installation method]:positioning hole
[Size]:80*50*30mm
[Introduction]:MA02-XACX0420 supports acquisition of 4-way sensor analog input (AI), conversion to serial port (RS232) data transmission to configuration software or PLC. The serial port I/O networking module (also known as "remote IO") is used to control 2 relay switch output (DO) by issuing instructions through the serial port.
Serial number | Pin | Pin direction | remarks |
---|---|---|---|
1 | DO2 | Switch output channel 2 | Relays have normal open and normal closed ends |
2 | DO1 | Switch output channel 1 | Relays have normal open and normal closed ends |
3 | AI2 | Simulate input channel 2 | It is recommended that RVV 2 x 0.5 wire |
4 | AI1 | Analog input channel 1 | It is recommended that RVV 2 x 0.5 wire |
5 | B/RX | RS485 corresponds to B | It is recommended that RVSP 3 x 0.5 wire |
6 | A/TX | RS485 corresponds to A | It is recommended that RVSP 3 x 0.5 wire |
7 | GND | Ground - | It is recommended that RVV 2 x 0.75 wire |
8 | VCC | Power supply . . | It is recommended that RVV 2 x 0.75 wire |
9 | AI4 | Analog input channel 4 | It is recommended that RVV 2 x 0.5 wire |
10 | AI3 | Analog input channel 3 | It is recommended that RVV 2 x 0.5 wire |